This document describes the MQTT protocol used for real-time communication with Navien NWP500 devices via AWS IoT Core.

Warning

This document describes the underlying MQTT protocol. Most users should use the Python client library (MQTT Client) instead of implementing the protocol directly.

Overview

Protocol: MQTT 3.1.1 over WebSockets Broker: AWS IoT Core Authentication: AWS SigV4 with temporary credentials Message Format: JSON

Topic Structure

Topics follow a hierarchical structure:

Command Topics

cmd/{deviceType}/{homeSeq}/{userSeq}/{clientId}/ctrl            # Control commands
cmd/{deviceType}/{homeSeq}/{userSeq}/{clientId}/st              # Status requests
cmd/{deviceType}/{homeSeq}/{userSeq}/{clientId}/res/{type}      # Responses

Event Topics

evt/{deviceType}/{homeSeq}/{userSeq}/app-connection  # App connection signal

Variables:

  • {deviceType} - Device type code (52 for NWP500)

  • {homeSeq} - Unique home/location identifier (assigned by Navien cloud system). Groups devices within the same home/installation and ensures messages are routed to the correct location. Retrieved from DeviceInfo.home_seq in the REST API.

  • {userSeq} - Unique user identifier for the account

  • {clientId} - MQTT client ID

  • {type} - Response type (status, info, energy-usage, etc.)

Message Structure

All MQTT messages are JSON with this structure:

{
  "clientID": "client-12345",
  "sessionID": "session-67890",
  "requestTopic": "cmd/52/25004/3456/client-12345/ctrl",
  "responseTopic": "cmd/52/25004/3456/client-12345/res/status/rd",
  "protocolVersion": 2,
  "request": {
    "command": 33554438,
    "deviceType": 52,
    "macAddress": "04786332fca0",
    "additionalValue": "...",
    "mode": "dhw-temperature",
    "param": [120],
    "paramStr": ""
  }
}

Fields:

  • clientID - MQTT client identifier

  • sessionID - Session identifier for tracking

  • requestTopic - Topic where command was sent (note: includes homeSeq and userSeq)

  • responseTopic - Topic to subscribe for responses

  • protocolVersion - Protocol version (always 2)

  • request - Command payload (see below)

Request Object

{
  "command": 33554438,
  "deviceType": 52,
  "macAddress": "04786332fca0",
  "additionalValue": "...",
  "mode": "dhw-temperature",
  "param": [120],
  "paramStr": ""
}

Fields:

  • command (int) - Command code (see Command Codes below)

  • deviceType (int) - Device type (52 for NWP500)

  • macAddress (str) - Device MAC address

  • additionalValue (str) - Additional device identifier

  • mode (str, optional) - Operation mode for control commands

  • param (array, optional) - Command parameters

  • paramStr (str) - Parameter string

  • month (array, optional) - Months for energy queries

  • year (int, optional) - Year for energy queries

Command Codes

Status and Info Requests

Command

Code

Description

Device Info Request

16777217

Request device features/capabilities

Device Status Request

16777219

Request current device status

Reservation Read

16777222

Read reservation schedule

Energy Usage Query

16777225

Query energy usage data

Control Commands

These commands control device operation, settings, and special functions.

Power Control

Command

Code

Description

Power Off

33554433

Turn device off

Power On

33554434

Turn device on

Operation Mode Control

Command

Code

Description

Set DHW Operation Mode

33554437

Change DHW heating mode (Heat Pump/Electric/Hybrid)

Set DHW Temperature

33554464

Set target water temperature

Scheduling and Reservations

Command

Code

Description

Update Weekly Reservations

33554438

Configure weekly temperature schedule

Configure TOU Schedule

33554439

Configure Time-of-Use pricing schedule

Configure Recirculation Schedule

33554440

Configure recirculation pump schedule

Configure Water Program (Reservation Mode)

33554441

Enable/configure water program reservation mode

Time-of-Use (TOU) Control

Command

Code

Description

Disable TOU

33554475

Disable TOU optimization

Enable TOU

33554476

Enable TOU optimization

Recirculation Pump Control

Command

Code

Description

Trigger Recirculation Hot Button

33554444

Manually activate recirculation pump

Set Recirculation Mode

33554445

Set recirculation operation mode

Special Functions

Command

Code

Description

Set Freeze Protection Temperature

33554451

Configure freeze protection activation temperature

Trigger Smart Diagnostic

33554455

Run smart diagnostic routine

Set Vacation Days

33554466

Configure vacation mode duration

Disable Intelligent Mode

33554467

Turn off intelligent/adaptive heating

Enable Intelligent Mode

33554468

Turn on intelligent/adaptive heating

Demand Response Control

Command

Code

Description

Disable Demand Response

33554469

Disable utility demand response

Enable Demand Response

33554470

Enable utility demand response

Anti-Legionella Control

Command

Code

Description

Disable Anti-Legionella

33554471

Disable anti-Legionella cycle

Enable Anti-Legionella

33554472

Enable anti-Legionella cycle

Maintenance

Command

Code

Description

Reset Air Filter

33554473

Reset air filter maintenance timer

Set Air Filter Life

33554474

Configure air filter replacement interval

Firmware Updates

Command

Code

Description

Commit OTA Update

33554442

Commit pending firmware update

Check for OTA Updates

33554443

Check for available firmware updates

WiFi Management

Command

Code

Description

Reconnect WiFi

33554446

Trigger WiFi reconnection

Reset WiFi

33554447

Reset WiFi settings

Control Command Details

Power Control

Power On:

{
  "command": 33554434,
  "mode": "power-on",
  "param": [],
  "paramStr": ""
}

Power Off:

{
  "command": 33554433,
  "mode": "power-off",
  "param": [],
  "paramStr": ""
}

DHW Mode

{
  "command": 33554437,
  "mode": "dhw-mode",
  "param": [3],
  "paramStr": ""
}

Mode Values:

  • 1 = Heat Pump Only

  • 2 = Electric Only

  • 3 = Energy Saver (Hybrid mode)

  • 4 = High Demand

  • 5 = Vacation (requires second param: days)

Vacation Mode Example:

When mode is 5 (VACATION), a second parameter specifies number of days:

{
  "command": 33554437,
  "mode": "dhw-mode",
  "param": [5, 7],
  "paramStr": ""
}

Note

Vacation mode is the only DHW mode that requires two parameters.

DHW Temperature

{
  "command": 33554464,
  "mode": "dhw-temperature",
  "param": [120],
  "paramStr": ""
}

Important

Temperature values are encoded in half-degrees Celsius. Use formula: fahrenheit = (param / 2.0) * 9/5 + 32 For 140°F, send param=120 (which is 60°C × 2). Valid range: Device-specific (see device features for dhw_temperature_min and dhw_temperature_max).

Anti-Legionella

Enable (7-day cycle):

{
  "command": 33554472,
  "mode": "anti-legionella-setting",
  "param": [2, 7],
  "paramStr": ""
}

Disable:

{
  "command": 33554471,
  "mode": "anti-legionella-setting",
  "param": [1],
  "paramStr": ""
}

TOU Enable/Disable

Enable or disable Time-of-Use optimization without changing the configured schedule.

Enable TOU (command 33554476):

{
  "command": 33554476,
  "mode": "tou-on",
  "param": [],
  "paramStr": ""
}

Disable TOU (command 33554475):

{
  "command": 33554475,
  "mode": "tou-off",
  "param": [],
  "paramStr": ""
}

Reservation Water Program

Enable/configure water program reservation mode.

Configure Reservation Mode (command 33554441):

{
  "command": 33554441,
  "mode": "reservation-mode",
  "param": [],
  "paramStr": ""
}

Note

This command enables or configures the water program reservation system.

Vacation Mode

Set vacation/away mode for extended periods.

Set Vacation Days (command 33554466):

{
  "command": 33554466,
  "mode": "goout-day",
  "param": [7]
}

Note

Vacation days parameter: Number of days (e.g., 7). Device will operate in energy-saving mode to minimize consumption during absence.

Intelligent/Adaptive Mode

Control intelligent heating that learns usage patterns.

Enable Intelligent Mode (command 33554468):

{
  "command": 33554468,
  "mode": "intelligent-on",
  "param": [],
  "paramStr": ""
}

Disable Intelligent Mode (command 33554467):

{
  "command": 33554467,
  "mode": "intelligent-off",
  "param": [],
  "paramStr": ""
}

Demand Response

Control utility demand response participation.

Enable Demand Response (command 33554470):

{
  "command": 33554470,
  "mode": "dr-on",
  "param": [],
  "paramStr": ""
}

Disable Demand Response (command 33554469):

{
  "command": 33554469,
  "mode": "dr-off",
  "param": [],
  "paramStr": ""
}

Note

Demand response allows utilities to manage grid load by signaling water heaters to reduce consumption (shed) or pre-heat (load up) before peak periods.

Recirculation Control

Control recirculation pump operation.

Hot Button (command 33554444):

{
  "command": 33554444,
  "mode": "recirc-hotbtn",
  "param": [1],
  "paramStr": ""
}

Note

The param array contains a parameter (typically 1 to activate).

Set Recirculation Mode (command 33554445):

{
  "command": 33554445,
  "mode": "recirc-mode",
  "param": [3],
  "paramStr": ""
}

Recirculation Mode Values:

  • 1 = Always On

  • 2 = Button Only (manual activation)

  • 3 = Schedule (follow configured schedule)

  • 4 = Temperature (activate when pipe temp drops)

Note: The param array contains a single integer parameter passed to the function.

Air Filter Maintenance

Manage air filter maintenance for heat pump models.

Reset Air Filter Timer (command 33554473):

{
  "command": 33554473,
  "mode": "air-filter-reset",
  "param": [],
  "paramStr": ""
}

Set Air Filter Life (command 33554474):

{
  "command": 33554474,
  "mode": "air-filter-life",
  "param": [180],
  "paramStr": ""
}

Note

Air filter life parameter: days between cleanings/replacements (typically 90-180 days)

Freeze Protection

Configure freeze protection settings.

Set Freeze Protection Temperature (command 33554451):

{
  "command": 33554451
}

Note

This command is defined in the enum but payload structure not found in decompiled code. May require additional parameters or use default payload.

Smart Diagnostics

Run smart diagnostic routine.

Trigger Smart Diagnostic (command 33554455):

{
  "command": 33554455
}

Note

This command is defined in the enum but payload structure not found in decompiled code. May require additional parameters or use default payload.

WiFi Management

Control WiFi connectivity.

Reconnect WiFi (command 33554446):

{
  "command": 33554446
}

Reset WiFi Settings (command 33554447):

{
  "command": 33554447
}

Warning

WiFi reset will clear stored credentials and require re-provisioning.

Note

These commands are defined in the enum but payload structures not found in decompiled code. They likely use minimal/default payloads.

Firmware Updates

Manage over-the-air firmware updates.

Commit Update (command 33554442):

This command uses a special RequestControlOta structure:

{
  "command": 33554442,
  "deviceType": 52,
  "macAddress": "...",
  "additionalValue": "...",
  "commitOta": {
    "swCode": 1,
    "swVersion": 184614912
  }
}

Note

  • swCode: Software component code (1=Controller, 2=Panel, 4=WiFi module)

  • swVersion: Version number to commit

  • This command does not use the standard mode/param/paramStr structure

Energy Usage Query

{
  "command": 16777225,
  "mode": "energy-usage-daily-query",
  "param": [],
  "paramStr": "",
  "year": 2024,
  "month": [10, 11, 12]
}

Response Messages

Status Response

{
  "clientID": "client-12345",
  "sessionID": "session-67890",
  "requestTopic": "...",
  "responseTopic": "...",
  "response": {
    "command": 16777219,
    "deviceType": 52,
    "macAddress": "...",
    "status": {
      "dhw_temperature": 120,
      "dhw_temperature_setting": 120,
      "current_inst_power": 450,
      "operationMode": 64,
      "dhwOperationSetting": 3,
      "operationBusy": 2,
      "compUse": 2,
      "heatUpperUse": 1,
      "errorCode": 0
    }
  }
}

Field Conversions:

  • Boolean fields: 1=false, 2=true

  • Temperature fields: Use HalfCelsiusToF formula: fahrenheit = (raw / 2.0) * 9/5 + 32

  • Enum fields: Map integers to enum values

See Device Status Fields for complete field reference.

Feature/Info Response

{
  "response": {
    "feature": {
      "controller_serial_number": "ABC123",
      "controller_sw_version": 184614912,
      "dhw_temperature_min": 75,
      "dhw_temperature_max": 130,
      "energy_usage_use": 1
    }
  }
}

See Device Feature Fields for complete field reference.

Energy Usage Response

{
  "response": {
    "typeOfUsage": "daily",
    "year": 2024,
    "data": [
      {
        "heUsage": 1200,
        "hpUsage": 3500,
        "heTime": 2,
        "hpTime": 8
      }
    ],
    "total": {
      "heUsage": 1200,
      "hpUsage": 3500
    }
  }
}

Connection Flow

  1. Authenticate

    Obtain AWS credentials from REST API sign-in.

  2. Connect MQTT

    Connect to AWS IoT endpoint using WebSocket with AWS SigV4 auth.

  3. Signal App Connection

    Publish to evt/52/{deviceId}/app-connection:

    {
      "clientID": "client-12345",
      "sessionID": "session-67890",
      "event": "app-connection"
    }
    
  4. Subscribe to Responses

    Subscribe to cmd/52/{clientId}/res/#

  5. Send Commands / Requests

    Publish commands to appropriate control/status topics.

  6. Receive Responses

    Process responses via subscribed topics.

Example: Request Status

1. Subscribe:

Topic: cmd/52/my-client-id/res/status/rd
QoS: 1

2. Publish Request:

Topic: cmd/52/04786332fca0/st/rd
QoS: 1
Payload:
{
  "clientID": "my-client-id",
  "sessionID": "my-session-id",
  "requestTopic": "cmd/52/04786332fca0/st/rd",
  "responseTopic": "cmd/52/my-client-id/res/status/rd",
  "protocolVersion": 2,
  "request": {
    "command": 16777219,
    "deviceType": 52,
    "macAddress": "04786332fca0",
    "additionalValue": "...",
    "mode": "",
    "param": [],
    "paramStr": ""
  }
}

3. Receive Response:

Response arrives on subscribed topic with device status.

Python Implementation

See MQTT Client for the Python client that implements this protocol.

Quick Example:

from nwp500 import NavienMqttClient

# Client handles all protocol details
mqtt = NavienMqttClient(auth)
await mqtt.connect()
await mqtt.subscribe_device_status(device, callback)
await mqtt.request_device_status(device)