Tank Energy

The NWP500 reports two energy figures, totalEnergyCapacity and availableEnergyCapacity. Both names mislead, and before v10.0 this library also scaled them wrongly. This page explains what they actually measure and shows the evidence for the correction.

The short version

Protocol field

What the name suggests

What it actually is

availableEnergyCapacity

Energy available in the tank

Energy still needed to reach the setpoint. It falls as the tank heats and hits zero when the tank is fully charged - the exact inverse of the name.

totalEnergyCapacity

Fixed tank capacity

Cost of a full recovery to the current setpoint. It moves whenever the setpoint moves.

Both are raw counts of 4 Wh each, not Watt-hours. Library versions before 10.0 multiplied by 10, overstating tank energy by 2.5x.

Both are also measured from the setpoint, so both describe potential rather than content: move the setpoint and both change while the water in the tank does not. Neither is a state of charge.

Their difference is a state of charge, and is exposed as DeviceStatus.usable_energy:

usable_energy = full_recovery_energy - energy_to_setpoint
              = k * (tank_temperature - 104.9 degF)

The setpoint cancels. What remains is the tank’s heat above the device’s minimum operating temperature - close enough to the lowest useful shower temperature that it is a good estimate of what you can actually draw.

How the fields behave

Both fields fit a single two-parameter model:

energy_to_setpoint    = k * (setpoint - tank_mean_temperature)
full_recovery_energy  = k * (setpoint - reference_temperature)

where k is the tank’s heat capacity and reference_temperature is the device’s own minimum setpoint, dhwTemperatureMin (40.5 degC / 104.9 degF) - though only about two thirds of the time, see Two branches.

Two consequences follow, and both matter:

  • energy_to_setpoint is a deficit. Code that treats it as stored energy has the signal backwards: it is largest when the tank is coldest.

  • full_recovery_energy is not a constant. Raising the setpoint by 0.5 degC raises it by 35 counts, about 140 Wh, on a 65-gallon tank. Seven months of history on one device shows sixteen distinct values as the setpoint was adjusted.

The evidence

Deficit, not stored energy

During a heating recovery on a 65-gallon unit at a 140.9 degF setpoint, with the tank warming and no draws. Each row is a mean over the samples in that temperature bin, so the counts are not whole numbers:

Mean tank temp

Setpoint minus tank

mean availableEnergyCapacity

dhwChargePer

119.5 degF

21.4 degF

881.6

54.5 %

127.4 degF

13.5 degF

530.0

69.5 %

135.1 degF

5.8 degF

227.5

85.7 %

The field falls as the tank fills with heat. Regressed against mean tank temperature over two weeks of five-minute samples, the slope is negative with an R-squared of 0.93 and a zero crossing at the setpoint.

The last two rows also check out against the tank’s heat capacity of 156 Wh/degF: 227.5 counts x 4 Wh = 910 Wh against 5.8 degF x 156 = 905 Wh, and 530.0 counts = 2120 Wh against 13.5 degF x 156 = 2106 Wh. The coldest row runs about 6 % high, which is the stratification error in using (upper + lower) / 2 as the mean tank temperature - it is worst when the tank is least mixed.

The 4 Wh quantum

totalEnergyCapacity is a whole-tank quantity, so its slope against the setpoint measures the quantum without needing any assumption about how the tank stratifies.

The device does not report a single totalEnergyCapacity per setpoint - see Two branches below - so the table lists the most common value at each setpoint, which covers 68 % of samples. Values are raw counts as they arrive on the wire:

Setpoint

totalEnergyCapacity

Setpoint

totalEnergyCapacity

140.0 degF

1369

144.5 degF

1545

140.9 degF

1404

145.4 degF

1580

141.8 degF

1439

146.3 degF

1615

142.7 degF

1475

147.2 degF

1650

143.6 degF

1510

148.1 degF

1685

An arithmetic sequence: least squares gives R-squared 0.99999 and a slope of 70.25 raw counts per Kelvin of whole-tank temperature rise. The endpoints alone give the same figure: (1685 - 1369) / 4.5 K = 70.2.

The slope is the robust part of this. The second branch, fitted separately, gives 38.98 counts/degF against the primary’s 39.06 - the same figure to within 0.2 %. Two independent populations agreeing on the slope is stronger evidence for the quantum than either alone.

Converting that to Watt-hours needs a water mass, and this is where care is required: a “65 gallon” tank does not hold 65 gallons of water. The nameplate is an upper bound - the vendor’s own app hard-codes it, mapping volumeCode 1/2/3 to 189.2 L, 246.0 L and 302.8 L (see What the vendor app does with these fields) - and the water actually in the tank must come in under it. Rather than assume nominal volume and derive an odd-looking quantum, assume the quantum is a round number - every other conversion in this protocol is (half-degrees, tenths) - and see which one implies a sensible volume:

Candidate quantum

Implied water volume

Plausible?

4 Wh (1/250 kWh)

241.7 L / 63.9 gal

Yes - slightly under nominal, as expected

1/240 kWh (4.167 Wh)

251.8 L / 66.5 gal

No - more than the nameplate

10 kJ

167.8 L / 44.3 gal

No

15 kJ

251.7 L / 66.5 gal

No

4 Wh per count is the only round candidate implying a volume below the nameplate, which is the only physically sensible direction. The library uses 4.0.

A second, noisier method agrees. Across 183 individual heating recoveries, dividing each tank sensible-heat gain (from the two thermistors and the nominal mass) by the device’s reported change gives a median of 4.11 Wh/count, p10 3.47 and p90 4.45. That route depends on (upper + lower) / 2 approximating the true mean tank temperature, so it is far less precise, but it is an independent confirmation and it does not use electrical input at all.

The efficiency cross-check

A third check rules out the old scale on its own. Integrating currentInstPower over each recovery gives the electrical energy in, and dividing the device’s reported energy gain by it gives an implied coefficient of performance:

Scale used

Implied COP (median)

Verdict

4 Wh/count (corrected)

2.89

Normal for a heat pump water heater

10 Wh/count (pre-10.0)

7.02

Physically impossible

A heat pump water heater in a 72 degF room runs at a COP of roughly 2 to 4. A COP of 7 would mean the device generated energy it never consumed.

This argument is worth stating separately because it needs no tank volume, specific heat or stratification model - only the device’s own reported energy and its own reported power. It cannot tell you what the quantum is, but it rules out the pre-10.0 value regardless of anything assumed elsewhere on this page.

Two branches

totalEnergyCapacity is not a function of the setpoint alone. At a fixed setpoint it takes one of two values, flipping between them several times a day. Over four months at nine setpoints:

Branch

Share

Slope

Zero crossing

Primary

68 %

39.06 counts/degF

104.95 degF

Secondary

32 %

38.98 counts/degF

108.48 degF

The two are parallel, separated by a constant 140-141 counts - exactly 2 degC of setpoint - at every setpoint measured.

The primary branch’s zero crossing matches the device’s dhwTemperatureMin of 104.9 degF to within a twentieth of a degree - 140.0 - 1369 / 39.06 = 104.95 degF - using only the device’s own two numbers: no tank mass, no specific heat, no thermistors, no assumption about the quantum. On that branch,

full_recovery_energy = k * (setpoint - dhwTemperatureMin)

The secondary branch behaves identically with a reference 2 degC higher, and what selects between them is unknown. The device’s hpUpperOnTempSetting correlates with the choice - 104.9 degF when the primary is active, 143.4 degF when the secondary is - which would fit the device computing recovery cost from its own turn-on threshold, but only 22 paired samples were available and that is a lead rather than a finding.

Warning

Because of this, do not derive the tank’s heat capacity from a live full_recovery_energy reading: landing on the wrong branch gives an error of about 9 %. Use the slope, which is stable across both branches, or compute stored energy from the thermistors directly.

What dhwChargePer does

dhwChargePer is a fourth signal and does not reconcile with the other two. On one device, energy_to_setpoint / full_recovery_energy implies 30 % charged while dhwChargePer reads 59 %; over two weeks the two differ by a mean of 48 points with 32 points of scatter.

It is nonetheless the number Navien shows its own users: the NaviLink app prints it unmodified as a percentage labelled “DHW Charge”, with no client-side arithmetic of any kind. Whatever it means, it is computed on the device, and a user comparing the app against this library will see the app’s figure and not the ratio above.

Treat it as an opaque vendor heuristic rather than a defined fraction of anything. For a charge figure with defined meaning, use usable_energy.

What the vendor app does with these fields

Nothing. Navien’s own NaviLink app never reads either field.

Decompiling the current release - version 2.03.00, versionCode 141, published March 2026 - gives 8,101 Java sources, and neither totalEnergyCapacity nor availableEnergyCapacity appears in any of them. Neither string appears in the raw dex string pool either, which rules out the names having been lost to obfuscation. The app’s status model, KDResponseMgppStatus.Status, declares about 140 fields - including dhwChargePer, tankUpperTemperature, tankLowerTemperature, currentInstPower and mixingRate - and neither energy field is among them. The app requests no field subset, so the device sends both and the app discards them on deserialization.

As a control, dhwChargePer and tankUpperTemperature are present in the dex strings, so the absence of the other two is a real result and not a broken search.

This matters for reading the rest of this page. There is no vendor label, no vendor scale factor and no vendor formula to check the conclusions above against - the evidence here is the only account of these two fields that exists. It also explains why the protocol names are so misleading: nothing Navien ships ever has to act on them.

The app does corroborate the surrounding facts this page leans on:

What the app does

What it confirms

MgppStatusFragment.getVolume() maps volumeCode 1/2/3 to “50”/”65”/”80” gallons and 189.2/246.0/302.8 L, displayed under the label “Volume”

The nominal volume the quantum candidates are judged against is the vendor’s own figure, not an assumption of ours

MgppControlFragment.makeTempMap() reads dhwTemperatureMin / 2.0f as degC before converting

dhwTemperatureMin is in half-degrees C, so 40.5 degC / 104.9 degF is the exact value the regression lands on. The app rounds for display and shows 105 degF

The status screen labels dhwTemperature “DHW Temp.” next to “Upper Temp.” and “Lower Temp.”, and gives dischargeTemperature a separate “Discharge Temp.” row

The vendor UI does not treat dhwTemperature as an outlet reading, and reserves a different field for what leaves the unit

Drawable energy

DeviceStatus.usable_energy is the difference of the two fields, and is the one number here that describes the tank’s state rather than its distance from a target:

usable_energy = full_recovery_energy - energy_to_setpoint

Raising the setpoint inflates both inputs equally, so the result does not move - which is what makes it a state of charge and the two raw fields not.

The implied reference is dhw_temperature_min, 104.9 degF. A shower runs around 105 degF, so heat below that reference is real but not useful, and excluding it is the behaviour you want. Note that a mixing valve does not change this floor: it caps how hot water can be delivered, and once the tank falls below its setting it simply passes through, so water stays usable down to the temperature you actually want at the tap.

Despite full_recovery_energy being bimodal (see Two branches), the difference is robust, because both fields shift together. Checked against the tank thermistors over 12275 samples, the tank temperature implied by usable_energy agrees with the thermistor mean to a standard deviation of 0.57 degF, with 97.5 % of samples inside 2 degF.

If you need a different floor - a bath at 100 degF, or energy above the cold inlet - compute it from the thermistors instead. On a 65-gallon tank the heat capacity is 156 Wh per degF:

drawable_Wh = 156 * (tank_mean_temperature - your_floor_degF)

Migrating from before v10.0

Old

New

status.total_energy_capacity (removed)

status.full_recovery_energy - and the value is 2.5x smaller

status.available_energy_capacity (removed)

status.energy_to_setpoint - 2.5x smaller, and note it was never “available”

Treating the value as available energy

It is a deficit; invert the logic. full_recovery_energy - energy_to_setpoint is the energy added above the device’s reference temperature

Treating the value as a percentage

It never was one

The old attribute names are removed rather than aliased, so a rename that is missed fails immediately with AttributeError instead of silently returning a number 2.5x too large.

If you logged these values historically, the stored series needs rescaling by 0.4 to be comparable with values from v10.0 onward.